AQUALAB Pure Gloss and Matte Water-Based Urethane Topcoat 1-Gallon Kit for a smooth finish on metallic and flake epoxy floors.
AQUALAB Urethane Pure Gloss / ... from $144.99
AQUALAB Pure Gloss | Water Based Urethane Epoxy Topcoat Product Overview AQUALAB Pure Gloss is a high performance, aliphatic water based urethane topcoat engineered to provide a professional grade protective shield over epoxy flooring. This two component (5 to 1) system delivers superior chemical resistance, elite abrasion resistance, and long term UV protection while maintaining a low odor application. This is the definitive choice for installers who need to protect warehouse and light duty commercial epoxy floors from premature wear, staining, and UV damage. The Aliphatic Advantage: Why Use a Urethane? While epoxy provides the structural build and "pop" for decorative floors, it is naturally susceptible to micro scratches and chemical staining. AQUALAB Pure Gloss adds an aliphatic urethane layer that is significantly harder and more resilient than epoxy. This is why most professional systems use a urethane or polyaspartic topcoat instead of leaving epoxy exposed. This results in: Extreme Scratch Resistance: Drastically reduces the "dulling" effect of foot traffic. UV Shielding: Unlike standard epoxy, this topcoat will not yellow and helps slow down the ambering of the epoxy layers beneath it. Stain Protection: Creates a non-porous surface that is much easier to clean and maintain in residential or commercial settings. Finish Options Gloss: Delivers a high-shine, glass like finish that maximizes color depth. Satin: Provides a refined, low-sheen look that hides surface imperfections and dust more effectively. Frequently Asked Questions Is this better than using epoxy as a topcoat?Yes. Aliphatic urethane topcoats provide significantly better chemical resistance, scratch resistance, and long term cleanability compared to standard epoxy alone. Does this product yellow?No. AQUALAB is non yellowing and contains UV inhibitors that help protect the underlying epoxy layers from direct sunlight. Can this be used indoors?Yes. The low odor, water based formulation is specifically designed for interior and occupied environments where solvent smells are not permitted. How many coats should I apply?We recommend two coats for the best durability and to ensure a perfectly uniform aesthetic finish across the entire floor. Can this be used over any epoxy?It is designed for use over properly prepared epoxy systems. If you are applying it over a different brand, we recommend a small adhesion test first. What is the mix ratio?The mix ratio is 5 parts Part A to 1 part Part B. Ensure you mix thoroughly for 2 to 3 minutes before application. What is the coverage rate?Coverage typically ranges from 500 to 600 square feet per kit on smooth surfaces and 400 to 500 square feet on partial flake epoxy floors. Can I add water to the mixture?No. Do not add water or solvents to the mixture. AQUALAB is formulated to be used exactly as it is packaged. How soon can I walk on the floor?The floor is typically ready for foot traffic after 24 hours of cure time at standard room temperatures. What is the best way to apply AQUALAB?Use the "dip and roll" method with a high-quality lint-free roller. This product is designed for dip and roll application rather than ribbon pour methods used with some other coatings.
LABPOX MVB FAST 3-Gallon Kit (Part A & B) 100% solids epoxy moisture vapor barrier for damp concrete and high RH slabs.
LABPOX MVB FAST | 100% Solids ... from $220.00
LABPOX MVB FAST | 100% Solids Epoxy Moisture Vapor Barrier LABPOX MVB FAST is a professional grade, 100% solids epoxy moisture vapor barrier designed to stop moisture before it destroys your floor. This system is engineered to bond to damp concrete slabs with up to 100 percent relative humidity, making it one of the most reliable solutions for moisture control in the industry. Moisture is the leading cause of epoxy floor failure. This product is designed to eliminate that risk and provide a stable foundation for epoxy, polyaspartic, and urethane flooring systems. If you are installing over a slab with unknown moisture conditions, this is not optional. This is your insurance policy. Performance and Moisture Control Up to 100% RH: Bonds directly to damp concrete and new concrete slabs less than 28 days old. Permeance: Less than 0.1 perm at 16 mils for maximum vapor protection. Moisture Reduction: Reduces emission rates from 25 lbs to less than 3 lbs per 1000 sq ft. Pinhole Mitigation Technology: Formulated to reduce surface defects and bubbles by up to 98 percent. Surface Preparation Requirements Proper preparation is mandatory. This product solves moisture problems, not surface contamination issues. Mechanical Preparation: Surface must be mechanically ground or shot blasted to a minimum CSP-2 or CSP-3 profile. Fiber Reinforced Concrete: All surface fibers must be completely removed by burning or grinding. Fibers act as conduits for moisture and will compromise the barrier if not fully encapsulated. Clean Surface: Concrete must be free of grease, oil, paint, or curing agents. Use a moisture meter to evaluate slab conditions. While this product bonds to high RH slabs, the surface must be free of standing moisture at the time of application. Radiant Heat: If a heated floor is installed, turn the system off 2 to 4 hours before application and keep it off for the duration of the cure. Mixing Instructions Proper mixing is critical to ensure the chemical properties of the moisture barrier activate correctly. Pre Mix Part A: Mix Part A at low speed before combining to ensure all pigments and solids are fully suspended. Mix Ratio: Combine 2 parts Part A with 1 part Part B in a clean container. Mix Time & Technique: Mix for 3 minutes using a Box Mixer and a low speed drill at 300 - 450 RPM. Immediate Placement: Once mixed, the material must be immediately poured onto the floor in ribbons. Leaving it in the pail will cause an exothermic reaction, making the product unusable. Application Apply using a 3/16 inch notch squeegee and back roll with an 18 inch roller to achieve a uniform film thickness. Work the material into the pores of the concrete to ensure full penetration. A minimum thickness ofย 16 to 18 mils is required to meet the permeance ratings for moisture mitigation. PRO TIP: This is a fast moving product. Once Part A and Part B are mixed, begin application immediately. Do not allow material to sit in the bucket. Extended dwell time will shorten working time and can lead to poor flow and inconsistent results. Coverage Rates and Permeance The vapor barrier performance of this product is directly proportional to the thickness of the coating. To ensure the permeance rating and performance of the barrier, Labsurface recommends a uniform film thickness of 16 to 18 mils. Thickness (Mils) Approx. Coverage 16 Mils (Recommended) 100 Sq. Ft. Per Gallon 14 Mils 114 Sq. Ft. Per Gallon 12 Mils 133 Sq. Ft. Per Gallon 4 to 6 Mils (Green Concrete Primer) 265 to 400 Sq. Ft. Per Gallon Frequently Asked Questions Can I broadcast vinyl flakes or other aggregates directly into MVB FAST?No. Broadcasting flakes or other aggregates directly into the moisture vapor barrier will decrease the moisture vapor resistance by as much as 75 percent. MVB FAST is a dedicated mitigation layer and must be applied as a standalone film at a uniform thickness to maintain its perm rating. You must apply a separate receiver coat over the barrier before broadcasting flakes. Do I really need a moisture vapor barrier?If you are unsure of the moisture levels in your slab, the answer is yes. Moisture is the leading cause of coating failure. Using MVB FAST is your insurance policy against delamination. Can this be applied to damp concrete?Yes. This product is designed to bond to concrete slabs with up to 100 percent relative humidity, provided the slab is completely dry to the touch at the time of installation. What happens if I have fiber reinforced concrete?Fibers can act as conduits for moisture to travel through your coating. You must burn or grind away all surface fibers and ensure a minimum 16 mil thickness to fully encapsulate them. How fast can I continue my flooring system?MVB FAST is engineered for speed. You can typically recoat in as little as 3 to 4 hours, allowing you to install a full system in a single day. What causes fisheyes or bubbling in the vapor barrier?Most issues are caused by surface contaminants or air movement. Ensure all HVAC vents are directed away from the floor and turn off all fans to prevent the material from skinning over prematurely. Can I use this over new concrete?Yes. This product can be applied to new concrete slabs that have been installed within 28 days, provided the surface humidity is controlled for at least three hours prior to installation. Why is reverse mixing recommended?Switching your mixer to reverse mode after 90 seconds forces the liquid from the bottom of the can to the top. This ensures a 100 percent homogeneous mixture which is critical for moisture mitigation. What is the maximum moisture reduction rate?When applied at the correct thickness, it reduces moisture emission rates from 25 lbs down to less than 3 lbs per 1000 square feet over 24 hours. Do I have to sand before applying my next coat?If you apply the next layer within the 24 hour recoat window, no sanding is required. After 24 hours, you must sand the surface to a dull finish to ensure a mechanical bond. Does this stop hydrostatic pressure?Very high levels of humidity may indicate hydrostatic pressure from a drainage failure or water leak. While MVB FAST is a powerful barrier, the source of any major water leaks should be addressed before installation.

5-Star Rated Business

Positive feedback from a growing number of happy customers

Hassle-Free Checkout

Search for products, add them to cart, and checkout with ease

Nationwide Shipping

Across the United States with no minimum order requirement

Satisfaction Guaranteed

We are a team of experienced floor installers ready to assist you